Need help with the Land Manager®?
Select from the list of frequently asked questions and troubleshooting tips below to find the answer.
Q: How do I perform a autogain?
A: Push system button, highlight calibration, press enter, highlight Auto gain and press enter.
Q: Do I need to limit the max channel output during a cal?
A: No, unless you are having trouble getting through an autogain.
Q: All I can see on the display is OFF.
A: Use the blue arrows to highlight channel, then push green button pointing to the right.
Q: The display only shows mph and area.
A: Push system button, scroll down to spd & area mon, press enter, press enter on disable spd & area mon, then press the operate button.
Q: I can’t see the display.
A: Press the green button up or down until you can see the screen again. (If this doesn’t work, press the blue up button one time then the green up or down buttons).
Q: The boom is not highlighted on the bottom of my screen.
A: Push system button, highlight and enter on configuration, highlight and enter on boom, highlight and enter on add/edit boom sections, highlight and enter on current section configuration, turn 12v on to off or off to on, press enter, then press the operate button.
Q: Can I switch J1 and J2?
A: No, each harness carries specific wires that can not be interchanged.
Q: How do I reset acres?
A: From operate screen, push operate button one time, from the accumulators screen, push clear button.
Q: How often do I need to do an autogain?
A: One time: Anytime a valve or sensor is replaced.
Q: Screen says cannot operate with current configuration.
A: Push system button, enter on configuration, make sure channel and boom type are the same.
To download files, right click the link and select "Save File" or "Save Target As."
You must have Adobe Reader in order to access PDF files. Download Adobe Reader.
Have a question that has not been answered? Complete the form below to send it.